• DE
  • Lösungen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt

STRIPECOIL

  • Stripecoil

Produktbeschreibung

Die passierbare und bodenschließende Rauchschürze. Stripecoil ist der optimale Rauchschutz in Personendurchgangsbereichen und auf Fluchtwegen - ausgelegt für die Temperaturklasse nach DIN EN 12101 bis D 120 (Hitzebeständigkeit über 120 Minuten bei einer Prüftemperatur von max. 600 °C) und DH 30 (Hitzebeständigkeit über 30 Minuten bei Prüftemperatur entsprechend der Einheits-Temperaturkurve (ETK)). Bereits bei einer Breite von 3 m können den Durchgang etwa 200 Personen (auch mit Kinderwagen und Rollstühlen) pro Minute passieren. Eine weiche und nachgiebige Schließkante der einzelnen Gewebestreifen trägt dazu bei, das Verletzungsrisiko zu minimieren. Das Schließen der Rauchschürze erfolgt ohne Fremdenergie mit dem Antriebssystem „Gravigen“.

BauartTextile Rauchschürze
VerwendbarkeitsnachweisCE nach DIN EN 12101-1
GewebeModutex 600 A2
NachweisZ - 56. 429 - 916 | 0761-CPD-0060
Schließrichtungvon oben nach unten
Schließzyklen1.000 Zyklen gemäß DIN EN 12101-1
KlassifizierungDH 30 | D 120 | Klassifizierung nach DIN EN 12101-1
AuslösungZugelassene Feststellanlage | Bauseitig

Konstruktiver Systemaufbau (Zwei Wickelwellen)

Stripecoil

Legende Systemkomponenten:
1 = Rauchmelder
2 = Gehäuse
3 = Befestigungskonsole
4 = Textil
5 = Abschlussleiste
6 = Rohrmotor
7 = Ansteuerungsmodul
8 = Steuerung mit Bedieneinheit
9 = Handauslöser

GewebeSystembreite (SB)Abrolllänge (AL)t (mm)h (mm)
Modutex 600 A2> 1,4 m - ≤ 2,7 m≤ 3,5 m330270
Modutex 600 A2> 2,7 m - ≤ 15 m≤ 3,5 m330200

Konstruktiver Systemaufbau (Eine Wickelwelle)

Stripecoil

Legende Systemkomponenten:
1 = Rauchmelder
2 = Gehäuse
3 = Befestigungskonsole
4 = Textil
5 = Abschlussleiste
6 = Rohrmotor
7 = Ansteuerungsmodul
8 = Steuerung mit Bedieneinheit
9 = Handauslöser

GewebeSystembreite (SB)Abrolllänge (AL)t (mm)h (mm)
Modutex 600 A2> 1 m - ≤ 1,8 m≤ 3,5 m190250
Modutex 600 A2≥ 1,8 m - ≤ 6 m≤ 3,5 m190225

Abschlussleisten


Abschlussleisten Stripecoil
Flexible Abschlussleiste
d = 24 mm


c = 05/175 mm

Einbauvarianten Gehäuse


Deckenmontage Stripecoil
Anbau an der Decke
Wandmontage Stripecoil
Anbau an der Wand (Sonder)

Gehäuse


Mehrwickel Stripecoil
Mehrwickel für Wandmontage
Mehrwickel Stripecoil
Mehrwickel für Decke (270)
SB = ≤ 2,7 m
Mehrwickel Stripecoil
Mehrwickel für Decke (200)
SB = > 2,7 m


Einwickel Stripecoil
Einwickel für Wandmontage
Einwickel Stripecoil
Einwickel für Deckenmontage

Führungsschienen


Führungsschiene Stripecoil
Standard
Führungsschiene Stripecoil
Seitliche Aufdopplung