• DE
  • Lösungen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt
Live-Brandversuche vor Ort

Live-Brandversuche vor Ort

Überzeugen Sie sich an unserem mobilen Brandversuchs-Container von der Leistungsfähigkeit moderner Brandschutztextilien

Überzeugen Sie sich an unserem mobilen Brandversuchs-Container von der Leistungsfähigkeit moderner Brandschutztextilien

Live-Brandversuche vor Ort

Ein Textil, dass einer Temperatur von mehr als 1000°C widersteht und dabei über mehrere Stunden intakt bleibt? Ein 1 mm dickes Gewebe, das den Wärmestrahlungsdurchgang vereinfacht gesagt um ca. 90% reduziert? Erleben Sie bei einem Live-Brandversuch die Leistungsfähigkeit moderner Brandschutztextilien!

Mit dem mobilen Brandcontainer können Sie sich hautnah von der Leistungsfähigkeit moderner textiler Brandschutzprodukte überzeugen. Der mobile und eigens für diese Demonstrationszwecke umgerüstete Binnencontainer kommt auf Messen oder bei Kundenveranstaltungen zum Einsatz. Im Container sind spezielle Stöbich-Brandschutzgewebe installiert, deren Schutzwirkung bei der Simulation einer Rauchentwicklung und -lenkung sowie bei einem simulierten Vollbrand im Containerinneren veranschaulicht wird. Zum Einsatz kommt beispielsweise ein Feuerschutzgewebe Heliotex und die passierbare Rauchschürze Stripecoil. Die Vorführungen finden grundsätzlich im Freien statt.

Brandschutzgewebe mit Klassifikation EW

Raumabschluss mit Begrenzung des Strahlungsdurchtritts

Am Beispiel des Gewebes Heliotex wird deutlich, wie stark der Strahlungsdurchtritt durch diesen Gewebetyp vermindert wird. Auszug: 13501-2 Klassifizierung von Bauprodukten und Bauarten: Die Strahlungsbegrenzung W ist die Fähigkeit eines Bauteils einer nur einseitigen Brandbeanspruchung so zu widerstehen, dass die Wahrscheinlichkeit einer Brandübertragung als Ergebnis signifikanter abgestrahlter Wärme entweder durch das Bauteil oder von der vom Feuer abgekehrten Oberfläche des Bauteils auf angrenzende Materialien reduziert wird. Es kann auch erforderlich sein, dass das Bauteil Personen in dessen Nähe schützen muss.

Einsatz von Rauchschürzen in Durchgangsbereichen

Die passierbare und bodenschließende Rauchschürze „Stripecoil“

Die passierbare Rauchschürze Stripecoil bietet im geschlossenen Zustand gleichzeitig Rauchschutz und Personendurchgang. Sie erfüllt somit die Funktionen der Rauchabschnittsbildung in Personendurchgangsbereichen bzw. Fluchtwegen und kann durch das Doppelwellensystem mit unbegrenzter Breite ausgeführt werden.

Stripecoil

Stripecoil

Die passierbare Rauchschürze, obwohl bodenschließend

Stripecoil