• NL
  • Oplossingen
    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Referenties
  • Over Stöbich
  • Wereldmarktleider
  • Duurzaamheid
  • Actueel
  • Contact

STRIPECOIL

  • Stripecoil

Productbeschrijving

Het doorloopbare rookscherm dat tot de vloer sluit. De Stripecoil is het rookscherm voor doorgangen in vluchtwegen en ontworpen voor de temperatuurklasse volgens NEN EN 12101 tot D120 (hittebestendigheid meer dan 120 minuten bij een testtemperatuur van max. 600 °C) en DH30 (hittebestendigheid meer dan 30 minuten bij testtemperatuur volgens de eenheidstemperatuurcurve. Vanaf een breedte van 3 meter kunnen er circa 200 personen (ook met kinderwagens en rolstoelen) per minuut de doorgang passeren. Een zachte en flexibele afsluitrand van de afzonderlijke weefselstroken draagt ertoe bij dat het letselrisico wordt geminimaliseerd. Het rookscherm sluit op zwaartekracht door middel van een ‘Fail Safe’ motor, een externe stroomvoorziening is daardoor niet benodigd en is brandwerende bekabeling overbodig.

Systeem typeTextiel rookscherm
Bewijs van bruikbaarheidCE volgens DIN EN 12101-1
WeefselModutex 600 A2
BewijsZ - 56. 429 - 916 | 0761-CPD-0060
Sluitrichtingvan boven naar beneden
Sluitingscycli1.000 cycli volgens DIN EN 12101-1
ClassificatieDH 30 | D 120 | Classificering volgens DIN EN 12101-1
ActiveringGoedgekeurd openhoudsysteem | door de fabrikant

Constructief systeemontwerp (Twee wikkelassen)

Stripecoil

Legendarische systeemcomponenten:
1 = Rookmelder
2 = Huisvesting
3 = Montagebeugel
4 = Textiel
5 = Einde strook
6 = Buismotor
7 = Regelmodule
8 = Besturing met bedieningseenheid
9 = Handmatige vrijgave

WeefselSysteembreedte (SB)Afrollengte (AL)t (mm)h (mm)
Modutex 600 A2> 1,4 m - ≤ 2,7 m≤ 3,5 m330270
Modutex 600 A2> 2,7 m - ≤ 15 m≤ 3,5 m330200

Constructief systeemontwerp (een wikkelas)

Stripecoil

Legendarische systeemcomponenten:
1 = Rookmelder
2 = Huisvesting
3 = Montagebeugel
4 = Textiel
5 = Einde strook
6 = Buismotor
7 = Regelmodule
8 = Besturing met bedieningseenheid
9 = Handmatige vrijgave

WeefselSysteembreedte (SB)Afrollengte (AL)t (mm)h (mm)
Modutex 600 A2> 1 m - ≤ 1,8 m≤ 3,5 m190250
Modutex 600 A2≥ 1,8 m - ≤ 6 m≤ 3,5 m190225

Afsluitlijsten


Afsluitlijsten Stripecoil
Flexibele afsluitlijst
d = 24 mm


c = 05/175 mm

Inbouwvarianten


Inbouwvarianten Stripecoil
Tegen het plafond gebouwd
Inbouwvarianten Stripecoil
Tegen de wand gebouwd (bijzonder)

Omkasting


Meervoudige wikkeling Stripecoil
Meervoudige wikkeling voor wandmontage
Meervoudige wikkeling Stripecoil
Meervoudige wikkeling voor plafond (270)
SB = ≤ 2,7 m
Meervoudige wikkeling Stripecoil
Meervoudige wikkeling voor plafond (200)
SB = > 2,7 m


Enkelvoudige wikkeling Stripecoil
Enkelvoudige wikkeling voor wandmontage
Enkelvoudige wikkeling Stripecoil
Enkelvoudige wikkeling voor plafondmontage

Geleiderails


Geleiderails Stripecoil
Standaard
Geleiderails Stripecoil
Zijdelingse verdubbeling