• DE
  • Lösungen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt
Sicherheit im Umgang mit Lithium-Ionen-Batterien

Sicherheit im Umgang mit Lithium-Ionen-Batterien

Sicherheit im Umgang mit Lithium-Ionen-Batterien

Durch ihre chemische Zusammensetzung bergen Lithium-Ionen-Batterien ein erhöhtes Brandrisiko. STÖBICH Lösungen schaffen Sicherheit – von der Brandfrüherkennung bis zur Gefahrgutverpackung für den Abtransport.

Immer wieder kommt es zu gefährlichen Unfällen, die im Zusammenhang mit Energiespeichern stehen. So kam es kürzlich in einem Recyclingbetrieb in Südfrankreich zu einem Großbrand, bei dem ➥ 900 Tonnen Lithium-Ionen-Batterien in Rauch aufgingen. Menschen gerieten dabei zum Glück nicht in Gefahr, aber das Feuer brannte noch bis in die Nacht.
Mit innovativen Lösungen zur Brandfrüherkennung wie dem ➥ Fire Multi Detector von STÖBICH können solche Ereignisse verhindert werden: Mittels optischer Sensoren erkennt das Multifunktionstool Hitze, Rauch und Flammen bereits, wenn ein Brand entsteht.

Ein anderes Thema ist der ADR-konforme Abtransport kritischer Lithium-Ionen-Batterien durch die Feuerwehr. Für diesen Fall haben wir spezielle Transportboxen in verschiedenen Größen entwickelt, die ➥ StrainBoxen. Die Freiwillige Feuerwehr Goslar arbeitet z. B. bereits seit Längerem mit diesen Brandschutzlösungen für Energiespeicher aus dem Hause STÖBICH.

© Shutterstock/Chris Mirek Freeman (Beispielbild)