• DE
  • Lösungen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt

Powerpack Typ 3 | Ohne Gehäuse

Powerpac Typ3

Produktbeschreibung

Das Powerpack ist ein Energiespeicher zum Überbrücken kurzer Netzausfälle bzw. Spannungsschwankungen der Einspeisespannung der Feststellanlage.

Das Powerpack ist wartungsfrei und hat eine Lebensdauer von bis zu 10 Jahren.

HerstellerProtronic Innovative Steuerungselektronik GmbH, Grimmaische Str. 92, D-04828 Bennewitz
maximale Betriebsspannung28 V
max. entnehmbarer Strom1 A, elektronische Abschaltung bei 1,4 A
Max. Ladestromansteigend bis auf ca. 80 mA
Aufladezeit (entladener Pack) ca. 50ca. 50 Minuten
Aufladezeit (Teilentladen)ca. 30 Minuten
Temperaturbereich-25 °C bis +40 °C
Überbrückungszeitmax. 10 min (abhängig von angeschlossener Last)
Lebensdauerbis zu 10 Jahren
VerbindungStecker 2 polig, von Jointech, Typ: A2501H-02P, Maße: 5,6 mm x 5,7 mm x 7,7 mm
Max. Maße118 x 27 x 55 mm (LxBxH)
Die Überbrückungszeit des Powerpack hängt von der angeschlossenen Last ab

Powerpack

Beispiel - Tabelle für gebräuchliche Gerätekombinationen

GerätekonfigurationLaststrom bei 24 VÜberbrückungszeit
RZ8 + 1x Haftmagnet0,115 Aca. 9 Minuten 48 Sekunden
RZ8 + AM-S0,350 Aca. 3 Minuten 28 Sekunden
RZ8 + 2x AM-S0,600 Aca. 2 Minuten 5 Sekunden
RZ8 + AM-U0,400 Aca. 3 Minuten 3 Sekunden
RZ8 + 2 x AM-U0,750 Aca. 1 Minute 42 Sekunden


Das Powerpack hält die Ausgangsspannung der Energieversorgung über den Überbrückungszeitraum konstant auf 22 VDC. Ist die gespeicherte Energie verbraucht, schaltet das PP3 die Ausgangsspannung auf 0 VDC ab.

ACHTUNG: Ein Kurzschluss des aufgeladenen Powerpacks kann die Elektronik beschädigen. Bitte das Powerpack nach einem Kurzschluss überprüfen und ggf. austauschen. Das defekte Powerpack kann in vielen Fällen repariert werden. Bitte dieses dazu unter Angabe einer QS Nummer an Protronic senden.

Hinweis:
Beim Einsatz des PP3 in einer Feststellanlage Typ RZ8 mit der aBZ Z-6.500-2436 aBG RZ8 RZ24-FA ist es nicht mehr erforderlich, den Schleifenwiderstand von 4k7 auf 5k9 zu ändern.

Hinweis:
Das Powerpack Typ 3 (PP3) ersetzt das Powerpack Typ 2 (PP2). Das PP3 ist abwärtskompatibel und kann somit als Ersatz ein PP2 verwendet werden.