• FR
  • Solutions
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Références
  • Mondes thématiques
  • Leader du marché mondial
  • Durabilité
  • Actualités
  • Contact

Powerpack type 3 | Sans boîtier

Powerpac Typ3

Description du produit

Le Powerpack est un accumulateur d'énergie permettant de surmonter les courtes pannes de réseau ou les fluctuations de la tension d'alimentation du dispositif de blocage.

Le Powerpack ne nécessite aucun entretien et a une durée de vie allant jusqu'à 10 ans.

FabricantProtronic Innovative Steuerungselektronik GmbH, Grimmaische Str. 92, D-04828 Bennewitz
Tension de service maximale28 V
courant maximal pouvant être prélevé1 A, coupure électronique à 1,4 A
Max. Courant de chargeCroissant jusqu'à environ 80 mA
Temps de recharge (pack déchargé) environ 50Environ 50 minutes
Temps de recharge (décharge partielle)Environ 30 minutes
Plage de température-25 °C à +40 °C
Temps de pontagemax. 10 min (dépend de la charge connectée)
Durée de vieJusqu'à 10 ans
ConnexionConnecteur 2 pôles, de Jointech, type : A2501H-02P, dimensions : 5,6 mm x 5,7 mm x 7,7 mm
Max. Dimensions118 x 27 x 55 mm (LxBxH)
Le temps de pontage du Powerpack dépend de la charge connectée.

Powerpack

Exemple - Tableau des combinaisons d'appareils usuels

Configuration des appareilsCourant de charge à 24 VTemps de pontage
RZ8 + 1x aimant de maintien0,115 Aenviron 9 minutes 48 secondes
RZ8 + AM-S0,350 Aenviron 3 minutes 28 secondes
RZ8 + 2x AM-S0,600 Aenv. 2 minutes 5 secondes
RZ8 + AM-U0,400 Aenviron 3 minutes 3 secondes
RZ8 + 2 x AM-U0,750 Aenviron 1 minute 42 secondes


Le Powerpack maintient la tension de sortie de l'alimentation en énergie à un niveau constant de 22 VDC pendant la période de bypass. Lorsque l'énergie stockée est consommée, le PP3 coupe la tension de sortie à 0 VDC.

ATTENTION: Un court-circuit du Powerpack chargé peut endommager l'électronique. Veuillez vérifier le Powerpack après un court-circuit et le remplacer si nécessaire. Dans de nombreux cas, le Powerpack défectueux peut être réparé. Veuillez l'envoyer à Protronic en indiquant un numéro d'assurance qualité.

Remarque:
En cas d'utilisation du PP3 dans un dispositif de blocage de type RZ8 avec l'aBZ Z-6.500-2436 aBG RZ8 RZ24-FA, il n'est plus nécessaire de modifier la résistance de boucle de 4k7 à 5k9.

Remarque:
Le Powerpack de type 3 (PP3) remplace le Powerpack de type 2 (PP2). Le PP3 est rétrocompatible et peut donc être utilisé en remplacement d'un PP2.