• DE
  • Lösungen
    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

      • Stoebich Fire & Smoke Curtain P
      • Stoebich Fire & Smoke Curtain E
      • Stoebich Fire & Smoke Curtain HC
      • Stoebich Fire & Smoke Curtain S
      • Stoebich Fire Curtain F
    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Omnicompact
      • Universal-S
      • ECClos®-FLEX-S
      • Turbocoil
      • GCC
      • Model RGT
    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

      • Stoebich Smoke Curtain P
      • Stoebich Smoke Curtain M
      • Stoebich Smoke Curtain X
      • Stoebich Smoke Curtain S
      • Fixed smoke curtain
      • Stoebich Smoke Curtain GX
    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

      • Stoebich Smoke Curtain T
      • Stoebich Smoke Curtain H
    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

      • Ecotube
      • Omnitube
    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • MoviPower 340/540
      • UPS
    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt

SYSTEM: SMOKESHIELD-S | BAUREIHE: SMOKESHIELD-S

  • Smokeshield-S

Produktbeschreibung

Rechteckige oder polygonförmige Grundfläche der Rauchschürze. Kantenabmessungen bis 16 m und Abrolllängen bis 6 m. Für eine hohe Zeitklasse und Temperaturbelastungen D 120 (600 °C). Ohne Restöffnungen - weder im oberen Bereich noch an den Ecken. Keine Stützen notwendig, trotzdem absolute Dichtigkeit auch bei hoher Druckbelastung. Niedrige Einbauhöhe des Gehäuses von ca. 125 mm bei einer AL < 3,0 m. Standardmäßig mit dem Antriebssystem „Gravigen“, d. h. Schließen ohne Fremdenergie, feuerresistente Kabel sind nicht nötig. Redundante Antriebssysteme als Absturzsicherung. Geeignet (zugelassen) auch als bodenschließende Rauchschürze.

FunktionTextile Rauchschürze
NachweisCE-Kennzeichnung nach DIN EN 12101-1:2005+A1:2006 | 0761-CPD-0060
GewebeEcotex 1100 A2
Schließrichtungvon oben nach unten
Schließzyklen1000 Zyklen nach DIN EN 12101-1:2005+A1:2006
FührungsartFührungsschienen | ohne Führungsschienen
KlassifizierungDH 120 | D 120 | Klassifizierung nach DIN EN 12101-1
AuslösungZugelassene Feststellanlage | Bauseitig
Smokeshield-S

Legende Systemkomponenten:
1 = Rauchmelder
2 = Gehäuse
3 = Führungsschiene
4 = Rohrmotor
5 = Textil
6 = Abschlussleiste
7 = Wickel
8 = Ansteuerungsmodul
9 = Steuerung mit Bedieneinheit
10 = Handauslöser

SL = Systemlänge
AL = Abrolllänge

Größenabmessungen und Systemaufbau

Durch die Kombination von Klassifizierungen oder das Verhältnis von lichter Systembreite zu lichter Systemhöhe können sich die genannten Maximalabmessungen reduzieren und die Abmessungen des Gehäuses und der Führungsschienen können variieren. Es gelten die Angaben auf dem Angebot.

GewebeSystemumfangAbrolllänge (AL)t (mm)h (mm)
Ecotex 1100 A2< 50 m< 3 m490125
Ecotex 1100 A2< 50 m> 3 m - ≤ 6 m490225

Abschlussleisten


Abschlussleisten Smokeshield-S
Standard

Gehäuse


Smokeshield-S Gehäuse
Standard
h = aus Tabelle
t = 490 mm

d = 290 mm
Smokeshield-S Gehäuse
Sonder
h = 125 mm
d = 290 mm
t = 490 mm

Führungsschienen


Typ 105 E (Nische)
Führung für offene Polygone
a = 117 mm
b = 278 mm