    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt
Produkt - Fibershield-E

Fibershield®-E

Der (E)conomische, textile Feuerschutzvorhang mit hohem Standardisierungsgrad

Produktbeschreibung

Hohe Standardisierung und damit ökonomisches Abschottungssystem mit Antriebssystem „Gravigen“, d.h. Schließen ohne Fremdenergien, sodass keine feuerresistenten Kabel nötig sind.

Hohe Zyklenzahl der Motoren von 10.000 Zyklen. Verschiedene Klassifizierungen durch unterschiedliche Gewebearten erreichbar. Große Feuerschutzvorhangsysteme mind. Klasse C 2.

Optionale Ausstattungsmöglichkeiten: Sicherheitskontaktleiste, federnde Abschlussleiste

Fibershield-E

Bauart

Textiler Feuerschutzvorhang

Erreichbare Schutzziele

EI - mit brandlastfreier Zone • EI - mit Sprinkler

Gewebe

Heliotex • Ecotex 1100 A2

Brandlastfreie Zone

Heliotex: EI 30/60/90min 20/30/50 cm • Protex/Ecotex: EI 30/60/90min 100/150/200 cm

Nachweis

UB III/B-06-005 • 3102/717/07 • UB 3.1/09-021 • UB III/B-08-012 • UB III/B-08-016

Schließrichtung

von oben nach unten

Feuerwiderstand

E 30 • E 60 • E 90 • EW 30 • EW 60 • klassifiziert nach DIN EN 13501-2

Schließzyklen

C2

  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
Konstruktiver Systemaufbau - Systemzeichnung

1Rauchmelder2Gehäuse3Führungsschiene4Befestigungskonsole5Textil6Abschlussleiste7Rohrmotor8Ansteuerungsmodul9Steuerung mit Bedieneinheit10Handauslöser


1Rauchmelder2Gehäuse3Führungsschiene4Befestigungskonsole5Textil6Abschlussleiste7Rohrmotor8Ansteuerungsmodul9Steuerung mit Bedieneinheit10Handauslöser

Klassifizierung

Gewebe

Systembreite

Abrolllänge

t

h

E 90 / EW 30

Ecotex 1100

≥ 1,1 m -≤ 3 m

≤ 3 m

200 mm

220 mm

EW 90

Heliotex EW

≥ 1,1 m -≤ 3 m

≤ 3 m

200 mm

220 mm

Sondergrößen auf Anfrage - Technisch bis zu einer Breite von 7 m (Ecotex 1100) bzw. 6 m (Heliotex) möglich

Abschlussleisten

Standard

Standard

Abschlussleisten - Standard

Sonder

Federnde Abschlussleiste

 - Federnde Abschlussleiste

TypSonder

Einbauvarianten Gehäuse

Wandmontage

An einer Abhängung

Deckenmontage

Führungsschienen

Standard

80 K

Führungsschienen - 80 K

a80 mmb60 mm

80 KB

Führungsschienen - 80 KB

a80 mmb60 mm

80 KN

Führungsschienen - 80 KN

a80 mmb60 mmaN85 mmbN70 mm