• DE
  • Lösungen
    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt
Produkt - Stripecoil

Stripecoil

Die passierbare Rauchschürze, obwohl bodenschließend

Produktbeschreibung

Die passierbare und bodenschließende Rauchschürze. Stripecoil ist der optimale Rauchschutz in Personendurchgangsbereichen und auf Fluchtwegen - ausgelegt für die Temperaturklasse nach DIN EN 12101 bis D 120 (Hitzebeständigkeit über 120 Minuten bei einer Prüftemperatur von max. 600 °C) und DH 30 (Hitzebeständigkeit über 30 Minuten bei Prüftemperatur entsprechend der Einheits-Temperaturkurve (ETK)). Bereits bei einer Breite von 3 m können den Durchgang etwa 200 Personen (auch mit Kinderwagen und Rollstühlen) pro Minute passieren. Eine weiche und nachgiebige Schließkante der einzelnen Gewebestreifen trägt dazu bei, das Verletzungsrisiko zu minimieren. Das Schließen der Rauchschürze erfolgt ohne Fremdenergie mit dem Antriebssystem „Gravigen“.

Stripecoil

Bauart

Textile Rauchschürze

Verwendbarkeitsnachweis

CE nach DIN EN 12101-1

Gewebe

Modutex 600 A2

Nachweis

Z - 56. 429 - 916 • 0761-CPD-0060

Schließrichtung

von oben nach unten

Schließzyklen

1.000 Zyklen gemäß DIN EN 12101-1

Klassifizierung

DH 30 • D 120 • Klassifizierung nach DIN EN 12101-1

Auslösung

Zugelassene Feststellanlage • Bauseitig

  • Stripecoil
  • Stripecoil
  • Stripecoil
  • Stripecoil
  • Stripecoil
Konstruktiver Systemaufbau - Zwei Wickelwellen

1Rauchmelder2Gehäuse3Befestigungskonsole4Textil5Abschlussleiste6Rohrmotor7Ansteuerungsmodul8Steuerung mit Bedieneinheit9Handauslöser


1Rauchmelder2Gehäuse3Befestigungskonsole4Textil5Abschlussleiste6Rohrmotor7Ansteuerungsmodul8Steuerung mit Bedieneinheit9Handauslöser

Gewebe

Systembreite

Abrolllänge

t

h

Modutex 600 A2

> 1,4 m - ≤ 2,7 m

≤ 3,5 m

330 mm

270 mm

Modutex 600 A2

> 2,7 m - ≤ 15 m

≤ 3,5 m

330 mm

200 mm

Konstruktiver Systemaufbau - Eine Wickelwelle

1Rauchmelder2Gehäuse3Befestigungskonsole4Textil5Abschlussleiste6Rohrmotor7Ansteuerungsmodul8Steuerung mit Bedieneinheit9Handauslöser


1Rauchmelder2Gehäuse3Befestigungskonsole4Textil5Abschlussleiste6Rohrmotor7Ansteuerungsmodul8Steuerung mit Bedieneinheit9Handauslöser

Gewebe

Systembreite

Abrolllänge

t

h

Modutex 600 A2

> 1 m - ≤ 1,8 m

≤ 3,5 m

190 mm

290 mm

Modutex 600 A2

> 1,8 m - ≤ 6 m

≤ 3,5 m

190 mm

225 mm

Abschlussleisten

Standard

flexible Abschlussleiste

Abschlussleisten - flexible Abschlussleiste

d24 mmc05/175 mm

Gehäuse

Standard

Mehrwickel für Wandmontage

Gehäuse - Mehrwickel für Wandmontage

Mehrwickel für Decke (270)

Gehäuse - Mehrwickel für Decke (270)

SB≤ 2,7 m

Mehrwickel für Decke (200)

Gehäuse - Mehrwickel für Decke (200)

SB> 2,7 m

Einwickel für Wandmontage

Gehäuse - Einwickel für Wandmontage

Einwickel für Deckenmontage

Gehäuse - Einwickel für Deckenmontage

Einbauvarianten Gehäuse

Anbau an der Decke

Anbau an der Wand (Sonder)

Führungsschienen

Standard

Standard

Führungsschienen - Standard

Seitliche Aufdopplung

Führungsschienen - Seitliche Aufdopplung

Referenzen

Produkt - Modehaus, Bertrange Luxemburg

Modehaus, Bertrange Luxemburg