• DE
  • Lösungen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenzen
  • Themenwelten
  • Weltmarktführer
  • Nachhaltigkeit
  • News
  • Jobs
  • Kontakt

ECClos®-S

ECClos-S

Produktbeschreibung

Der Blechpaneel-Schieber zeichnet sich durch seine robuste Sandwichbauweise mit allseitiger Blechhülle aus. Er eignet sich für unterbrochene und durchgehende Fördersysteme wie Gurt-, Rollenund Tragkettenförderer. Segmentierte Schieberelemente erlauben einen reibungslosen Transport zum Einbauort. Variable Festfelder ermöglichen die einfache Umsetzung kundenspezifischer Lösungen.

BauartFeuerschutzabschluss im Zuge bahngebundener Förderanlagen
VerwendbarkeitsnachweisEuropean Technical Assessment - ETA (EU) | Certificate of Constancy of Performance (UK) | VKF Technische Auskunft Nr. 32211
Schließrichtungvon oben nach unten | von links nach rechts | von rechts nach links
FeuerwiderstandEI₁ 120
SchließzyklenC5 Anzahl der Schließzyklen 200.000 | klassifiziert nach DIN EN 13501-2
Wiederöffnungelektromotorisch (Standard) | manuell
FördersystemSkid-Förderer | Gefällebahn | Unterbrochene Fördertechnik | Durchgehende Gurtfördertechnik | Durchgehender Verfahrwagen | Durchgehende Tragkettenfördertechnik | Durchgehende Rollenfördertechnik | Durchgehende Fördertechnik

Konstruktiver Systemaufbau (Vertikal)

ECClos-S
a = 245 | b = 660 | c = 550/625 | e = ≥ 0 | s = 122
Benötigte Wandqualität
Mauerwerkd ≥ 200 mm
Betond ≥ 200 mm
Porenbetond ≥ 200 mm
Montagewänded ≥ 160 mm
Beplankter Stahlbaunach DIN 4102-4

Zulassungsbereich (12,1 m² vertikale Schließrichtung)
LBbis 4500 mm
LHbis 4500 mm

Technische Machbarkeit (max 20,25 m²)
LBbis 4500 mm
LHbis 5100 mm

Konstruktiver Systemaufbau (Horizontal)

ECClos-S
a = 187 | b = 590 | c = 410 | f = ≥ 164 | i = 410 | j = 150 | s = 122
Benötigte Wandqualität
Mauerwerkd ≥ 200mm
Betond ≥ 200mm
Porenbetond ≥ 200mm
Montagewänded ≥ 160mm
Beplankter Stahlbaunach DIN 4102-4

Zulassungsbereich (13,5 m² horizontale Schließrichtung)
LB4500 mm
LH4500 mm

Technische Machbarkeit
LB4500 mm
LH5100 mm