• NL
  • Oplossingen
    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Referenties
  • Over Stöbich
  • Wereldmarktleider
  • Duurzaamheid
  • Actueel
  • Contact

SYSTEEM: OMNICOMPACT-CSC

Omnicompact-FAA

Productbeschrijving

In geval van alarm zelfsluitende, brandwerende brandwerende afsluiting in de vorm van een hefpoort met gescheiden transporttechniek.

TypeBrandwerende afsluiting in het kader van afzonderlijke transportinstallaties in de vorm van een hefpoort
CertificeringAlgemene typegoedkeuring Z-6.22-2664; volgens EN 16034:2014 in combinatie met EN 13241:2003+A2:2016
Sluitingsrichtingvan boven naar beneden
BrandweerstandEI2 90 | getest volgens EN 1634-1:2014-03 | geclassificeerd volgens EN 13501-2:2023
SluitingscycliC2 | getest volgens EN 12605:2000-08 | geclassificeerd volgens EN 13501-2:2023
MilieuomstandighedenNiet in aanmerking genomen zijn bijzondere omgevingsomstandigheden (bv. vochtigheid > 80%, omgevingstemperatuur < 5 °C en > 45 °C, windbelasting, enz.)
Zichtbare oppervlakken van de behuizing en de geleiderailsGegalvaniseerd | RAL - glad - zijdeglans - standaard kleurtint | NCS - standaard kleurtint
Omnicompact-FAA

Delen van het systeem:
1 = Rookmelder
2 = Geleiderails
3 = Montagebeugel
4 = Lamel
5 = Eindelement
6 = Aandrijfmotor
7 = Besturing met bedieningseenheid
8 = Handmatige ontgrendeling optioneel (handmatige ontgrendeling vereist als de bediening met bedieningseenheid hoger is dan 1,4 m boven de bovenkant van de afgewerkte vloer)

Wettelijke afmetingen:
Lichaam
q = vrije onafgewerkte hoogte
x = onbewerkte breedte
systeem
s = systeemhoogte
y = systeembreedte vrijmaken
z = systeembreedte
behuizing
t = diepte
t1 = Console
t2 = Ruimtebeslag besturingskast plafond
h = Hoogte
v = Offset tussen geleiderail en wikkelhuis
geleiderail
a = breedte
b = diepte
Transportband
f = Breedte van de scheidingsplaats (>107 mm)

Afmetingen en structuur van het systeem

De afmetingen van de consoles en de geleiderails kunnen variëren. De gegevens op de offerte zijn van toepassing.

BrandwerendheidsklasseMax. afmetingen* [x x q] in mmWeefsel/onderdeelWanddikte** in mmConsoleGeleidingsrails
EI2 906000 x 5600Lamelle≥ 240A, B, CTyp 1
C26000 x 5600Lamelle


De installatiesituatie moet voldoen aan de bouwvoorschriften van het land van installatie. De brandwerendheid van een plafond- of wanddraagconstructie en de aangrenzende onderdelen moet ten minste overeenkomen met die van de brand- en/of rookwerende afsluiting/brand- en/of rookwerend gordijn. De stabiliteit en bruikbaarheid van de aangrenzende wanden en onderdelen moeten worden aangetoond onder algemene omgevingsomstandigheden en in geval van brand. Zie ook de opmerkingen over de standaard draagconstructie in EN 1366-7:2004 of EN 1363-1:2020. Het brandbeveiligingssysteem mag ook in geval van brand niet extra worden belast, afgezien van zijn eigen gewicht.
* Afwijkingen van de afmetingen op aanvraag
** geteste wandtypes volgens de installatievoorschriften

Console


Omnicompact
Overlappende latei en verticale afdichtingslijst met beugel
Type A
Omnicompact
Ophanging van aandrijfas voor vrije bouwbreedte > 4500 mm via galgen
Type B
Omnicompact
Ophanging van aandrijfas met vrije onafgewerkte breedte > 4500 mm boven plafond
Type C

Geleiderails


Omnicompact-FAA
Typ 1
Omnicompact-FAA