• EN
  • Solutions
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • References
  • Theme worlds
  • World market leader
  • Sustainability
  • News
  • Contact

SYSTEM: OMNICOMPACT-CSC

Omnicompact-FAA

Product description

In the event of an alarm, self-closing, fire-resistant fire protection closure in the design of a lift-and-slide door with separate conveyor technology.

TypeFire protection closure in the course of separate conveyor systems in the design of a lift-and-slide gate
CertificationGeneral type approval Z-6.22-2664; in accordance with EN 16034:2014 in conjunction with EN 13241:2003+A2:2016
Closing directionfrom top to bottom
Fire resistanceEI2 90 | tested in accordance with EN 1634-1:2014-03 | classified in accordance with EN 13501-2:2023
Closing cyclesC2 | tested in accordance with EN 12605:2000-08 | classified in accordance with EN 13501-2:2023
Environmental conditionsNot considered are special environmental conditions (e.g. humidity > 80%, ambient temperature < 5 °C and > 45 °C, wind loads, etc.)
Visible surfaces of the housing and guide railsGalvanised | RAL - smooth - silk gloss - standard colour shade | NCS - standard colour shade
Omnicompact-FAA

Legendary system components:
1 = Smoke detector
2 = Guide rails
3 = Mounting bracket
4 = Slat
5 = End element
6 = Drive motor
7 = Control with operating unit
8 = Manual release optional (manual release required if the control with operating unit is higher than 1.4 m above the upper edge of the finished floor)

.

Legal dimensioning:
Body
q = clear unfinished height
x = clear unfinished width
System
s = system height
y = clear system width
z = system width
Housing
t = depth
t1 = Console
t2 = Space requirement control box ceiling
h = Height
v = Offset between guide rail and winding housing
Guide rail
a = width
b = depth
Conveyor system
f = Separation point width (>107 mm)

Size dimensions and system structure

The dimensions of the brackets and guide rails may vary. The information provided in the quotation applies.

Fire resistance classSize max.* [x x q] in mmFabric/componentWall thickness** in mmConsoleGuide rails
EI2 906000 x 5600Lamella≥ 240A, B, CType 1
C26000 x 5600Lamella


The installation situation must comply with the building code requirements of the country of installation. The fire resistance of a ceiling or wall support structure and the adjoining components must at least correspond to that of the fire and/or smoke protection closure/fire and/or smoke protection curtain. Proof of the stability and serviceability of the adjacent walls and components must be provided under general ambient conditions and in the event of fire. See also notes on the standard supporting structure in EN 1366-7:2004 or EN 1363-1:2020. The fire protection system must not be subjected to any additional load apart from its own weight, even in the event of fire.
* Deviations from size dimensions on request
** tested wall types according to the installation instructions

Console


Omnicompact
Overlapping lintel and vertical sealing frame with bracket
Type A
Omnicompact
Suspension of drive shaft with clear structural width > 4500 mm via gallows
Type B
Omnicompact
Suspension of drive shaft with clear unfinished width > 4500 mm above ceiling
Type C

Guide rails


Omnicompact-FAA
Typ 1
Omnicompact-FAA