• NL
  • Oplossingen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenties
  • Over Stöbich
  • Wereldmarktleider
  • Duurzaamheid
  • Actueel
  • Contact

SYSTEEM: GCC

GCC

Productbeschrijving

Enkelblads, verticaal en horizontaal sluitende brandbeveiliging voor wandopeningen van railgebonden transportsystemen. Transportsystemen; gescheiden en niet-gescheiden transportsystemen in de afsluitzone.

Type constructieBrandwerende afsluiting in de loop van spoorgebonden transportsystemen
Bewijs van bruikbaarheidETA-16/0851 Europese technische beoordeling | VKF Technische informatie Nr. 32235
Richting van sluitingvan boven naar beneden | van links naar rechts | van rechts naar links
BrandweerstandEI1 90 | getest volgens DIN EN 1366-7:2004 | geclassificeerd volgens EN 13501-2:2007
SluitingscycliC4 | Aantal sluitcycli 100.000 | Verticale sluitrichting
C5 | Aantal sluitcycli 200.000 | horizontale sluitrichting
Heropening gemotoriseerd
TransportsysteemOnonderbroken transportsysteem | Hellend transportsysteem | Continu bandtransportsysteem | Continue Continue hangkettingbaantechnologie | Continue rollenbaantechnologie | Continue transportbandtechnologie
Zichtbare oppervlakkenVerankeringsdelen:
gegalvaniseerd | gecoat in RAL-kleur | roestvrij staal 1.4301 (V2A)

Festpaneel en klepblad:
onbehandelde brandwerende platen | geverfd met dispersieverf in een vergelijkbare RAL-kleur | verzinkte plaatstalen beplating | plaatstalen beplating roestvrij staal 1.4301 (V2A) | plaatstalen beplating gecoat in RAL-kleur

Afmetingen en systeemontwerp

Door de combinatie van indelingen of de verhouding tussen de vrije systeembreedte en de vrije systeemhoogte kunnen de opgegeven maximumafmetingen kleiner zijn en kunnen de afmetingen van de kast en de geleiderails variëren. De details op de offerte zijn van toepassing.

Component (dragende structuur) waarin de sluiting kan worden geïnstalleerdBeschikbare brandwerendheidsklasse
Klare wandopening
grootste breedte LBgrootste hoogte LHGrootste oppervlakte
Stevige wand met hoge dichtheid, metselwerk of massief beton met
totale dichtheid van ≥ 800 kg/m3 en een dikte ≥ 150 mm
EI1 90
EI2 90
3.600 mm4.200 mm10,0 m2
Lage dichtheid massieve wand, cellenbeton met totale dichtheid
van ≥ 450 kg/m3 en een dikte ≥ 150 mm
EI1 90
EI2 90
3.600 mm4.200 mm10,0 m2


De inbouwsituatie moet voldoen aan de bouwvoorschriften van het land van inbouw. De brandwerendheid van een plafond- of wanddraagconstructie en de aangrenzende bouwdelen moet ten minste overeenkomen met die van de brand- en/of rookwerende afsluiting/brand- en/of rookwerend gordijn. De stabiliteit en bruikbaarheid van de aangrenzende wanden en onderdelen moeten worden aangetoond onder algemene omgevingsomstandigheden en in geval van brand. Zie ook de opmerkingen over de standaard draagconstructie in EN1366-7:2004 of EN1363-1:2020. Het brandbeveiligingssysteem mag ook in geval van brand niet worden blootgesteld aan andere belastingen dan zijn eigen gewicht.

Ontwerp van structurele systemen (verticaal)

Fibershield-I
a = 155 | c = 570 | f = 70 | s = 51

Ontwerp van structurele systemen (horizontaal)

Fibershield-I
b = 260 | c = 270 | d = 500 | f = 70 | i = 425 | s = 51