• EN
  • World market leader
  • Sustainability
  • Solutions
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-H
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Omnicompact
      • Universal-S
      • ECClos®-FLEX-S
      • Collar
      • Turbocoil
      • GCC
      • RGT
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Moducoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
      • Fiberseal-H
    • Tube sealings

      Tube sealings

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Ecotube
      • Omnitube
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
  • References
  • Theme worlds
  • News
  • Contact

Fire Multi Detector

Fire Multi Detector

Product description

The core of the solution for prevention - especially of large fires - is the reduction of the time between and fire detection by using optical-thermal detectors in combination with the patented detection software.

This makes it possible to detect smoke, temperatures and natural flames with just one detector. Interference variables such as clouds, sun, fog, dust or heat-emitting vehicles do not lead to false alarms. This makes this solution is excellently suited for indoor and outdoor use, especially for large monitoring areas.

The 24/7 availability ensures a high level of security in conjunction with intelligent information processing and ensures that all necessary agencies are immediately informed, alerted and provided with important additional information.

With this solution, large fires with all their drastic consequences for people, operations and the environment are a thing of the past.

Main featuresMonitoring of indoor, outdoor and dynamic areas (conveyor belts)Daily and time-dependent detection parameters possible
Colour and intensity-based flame and smoke detection analyses result in a high detection rate and minimised false alarms.Secure transmission of alarms with live still image into the SMC app enables visual review of incidents and improved situational awareness.
The Fire Multi Detector has a built-in thermopile module that analyses temperatures in the detection area.Neutralisation of the occurring harmful gases
Internal recording enables the verification and analysis of events

Product Features

Technical data
FMD 10
FMD 35
Dimensions L x B x H
373 x 263 x 100 mm
Operating voltage
312–24 V DC (PoE possible)
Power
4,5 W
Protection class
IP66
Operating temperature
Operation: -20 °C bis 50 °C
Storage: -10 °C bis 70 °C
Humidity during operation
20 % to 80 % relative humidity (non-condensing)
Weight
3,0 kg
Approvals
CE marking, complies with Part 15 of the FCC CFR47, RoHS compliant
Distance
up to 30 m
up to 80 m
Detection range optical
H: 85° · V: 63°
H: 34° · V: 25°
Detection range thermal
H: 90°
H: 39°
Resolution thermal
H: 82 px · V: 62 px
Temperature range
-30 °C to 300 °C
Monitoring area
30 cm Fire: 70 m²
60 cm Fire: 290 m²
30 cm Fire: 450 m²
60 cm Fire: 1.850 m²
Detection
Flame, smoke and temperature detection
Image sensor
1/4 inch CMOS with progressive scan
Automatic gain control AGC
Automatic and manual
WDR image enhancement
>80 dB
Signal-to-noise ratio
>50 dB
Minimum lighting
20 lx (lux) IR floodlight, required for smoke detec-
tion. Fire detection and temperature monitoring
are fully functional in complete darkness.
Storage capacity
Integrated recording on internal SD card (up to 64 GB)
Available archiving formats
JPEG und MPEG-4
Alarms and relays
4 potential-free relay outputs Relay 1-3: 600 mA at 60 V DC Relay 4: 2.2 A at 60 V DC