• EN
  • World market leader
  • Sustainability
  • Solutions
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

    • Tube sealings

      Tube sealings

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

  • References
  • Theme worlds
  • News
  • Contact
FeuerTRUTZ 2016 - Stöbich live fire tests

FeuerTRUTZ 2016 - Stöbich live fire tests

Photos and video of the 'Fire protection' promotion area

Photos and video of the 'Fire protection' promotion area

FeuerTRUTZ 2016 - Stöbich live fire tests

In 2016, the trade visitors were amazed again by Stöbich's mobile fire container that was set up on the 'fire protection promotion area'. As in previous years, the visitors' interest in experiencing textile fire protection live and close up was huge. The live demonstrations took place twice a day at 12 o'clock and 3 pm outdoors on the exhibition grounds.

A textile that can withstand a temperature of more than 1000 °C and remain intact for several hours? A fabric with a thickness of 1 mm which reduces the passage of radiation by approx. 90 % (to put it simply)? A floor-closing smoke protection curtain with a passage element?

There is a lot of development effort that goes into the production of these high-tech fabrics including complex weaving, coating and lamination techniques. The result of modern production procedures are highly durable composite surfaces made of fabrics, metallic or plastic films. These multi-layer textiles offer fire resistance classes up to a classification of E 240 and also limit the radiation penetration (EW classification) to up to 120 minutes.

  • Feuertrutz exhibition: more than just smoke detectors