      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • References
  • Theme worlds
  • World market leader
  • Sustainability
  • News
  • Contact
Product - Stripecoil

Stripecoil

The passable but still floor-closing smoke apron

Product description

The passable and floor-closing smoke apron. Stripecoil is the optimum smoke protection for foot traffic areas and escape routes - designed for the temperature class according to DIN EN 12101 to D120 (heat resistance over 120 minutes at a test temperature of max. 600°C) and DH30 (heat resistance over 30 minutes at test temperature according to the unit temperature curve. A width of only 3 m is sufficient to allow about 200 people ( including prams and wheelchairs) to pass through the passage per minute. A soft and yielding closing edge of the individual fabric strips helps to minimize the risk of injury. The smoke barrier closes without external energy thanks to the "Gravigen" drive system.

Stripecoil

Type

Textile smoke apron

Proof of usability

CE according to DIN EN 12101-1

Fabric

Modutex 600 A2

Verification

Z - 56. 429 - 916 • 0761-CPD-0060

Closing direction

From top to bottom

Closing cycles

1,000 cycles according to DIN EN 12101-1

Classification

DH 30 • D 120 • Classification according to DIN EN 12101-1

Triggering

Approved hold-open system • To be provided on site

  • Stripecoil
  • Stripecoil
  • Stripecoil
  • Stripecoil
  • Stripecoil
Constructive system design - Two winding shafts

1Smoke detector2Casing3Side guide4Fixing bracket5Fabric6Closing element7Tubular motor8Control module9Control with operating unit10Manual release


1Smoke detector2Casing3Side guide4Fixing bracket5Fabric6Closing element7Tubular motor8Control module9Control with operating unit10Manual release

Fabric

System width

Drop length

t

h

Modutex 600 A2

> 1.4 m - ≤ 2.7 m

≤ 3.5 m

330 mm

270 mm

Modutex 600 A2

> 2.7 m - ≤ 15 m

≤ 3.5 m

330 mm

200 mm

Constructive system design - One winding shaft

1Smoke detector2Casing3Side guide4Fixing bracket5Fabric6Closing element7Tubular motor8Control module9Control with operating unit10Manual release


1Smoke detector2Casing3Side guide4Fixing bracket5Fabric6Closing element7Tubular motor8Control module9Control with operating unit10Manual release

Fabric

System width

Drop length

t

h

Modutex 600 A2

> 1 m - ≤ 1.8 m

≤ 3.5 m

190 mm

290 mm

Modutex 600 A2

> 1.8 m - ≤ 6 m

≤ 3.5 m

190 mm

225 mm

Closing strips

Standard

Flexible closing strip

Closing strips - Flexible closing strip

Casing

Standard

Multi-coil for wall mounting

Casing - Multi-coil for wall mounting

Multi-coil for ceiling (270)

Casing - Multi-coil for ceiling (270)

SB≤ 2,7 m

Multi-coil for ceiling (200)

Casing - Multi-coil for ceiling (200)

SB> 2,7 m

Single-coil for wall mounting

Casing - Single-coil for wall mounting

Single-coil for ceiling mounting

Casing - Single-coil for ceiling mounting

Casing installation options

Ceiling mounting

Wall mounting (special purpose)

Guide rails

Standard

Standard

Guide rails - Standard

Lateral doubling

Guide rails - Lateral doubling