• EN
  • Solutions
    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • References
  • Theme worlds
  • World market leader
  • Sustainability
  • News
  • Contact
Product - Fibershield-F

Fibershield®-F

The textile fire protection curtain for openings in façades, installation outside a building

Product description

The textile fire protection closure for openings in façades for installation outside buildings

Efficient long-term and weather-resistant fire protection: Fibershield-F is made of components that are tried and tested for outdoor use and offer many options for attachment to a wide variety of façades (with or without thermal insulation, with combustible or non-combustible insulation).

Drive and guide rails are heated regardless of the ambient temperature to ensure that, in the event of low temperatures, the gravity-fail-safe function works and that the lateral guide rails do not ice up.

Fibershield-F

Type

Textile fire protection curtain

Achievable protection goals

EI - with fire load free zone • EW 90

Fabric

Protex 1100 2S • Heliotex

Fire load free zone

Protex/Ecotex: EI 30/60/90min 100/150/200 cm • Heliotex: EI 30/60/90min 20/30/50 cm

Verification

GU IV/97-73 • UB III/B-08-012 • B 15045 • UB III/B-05-006-A1

Closing direction

From top to bottom

Fire resistance

E 30 • E 60 • E 90 • E 120 • EW 30 • EW 60

Closing cycles

C2

Feasible size

(F) Depending on fabric typeHeliotex: 5 x 2 m / 5 x 6 m (w x h) • (F) Depending on fabric typeProtex: 5 x 6 m / 6 x 7 m (w x h)

Guide type

Guide rails

Bearing

Fixed bearing

Re-opening

Gravity-Fail-Safe • self-closing

  • Fibershield-F
  • Fibershield-F
  • Fibershield-F
Constructive system design - System drawing

Fabric

System width

Drop length

t (mm)

h (mm)

Heliotex EW

≥ 0.8m - ≤ 5 m

≤ 2 m

190

250

Heliotex EW

≥ 0.8m - ≤ 5 m

≤ 5 m

235

290

Ecotex 1100 2S

≥ 0.8m - ≤ 1.6 m

< 3.5 m

190

250

Ecotex 1100 2S

≥ 1.6m - ≤ 5 m

< 3.5 m

190

200

Ecotex 1100 2S

≥ 0.8m - ≤ 5 m

> 3.5 m - ≤ 5 m

190

250

Closing strips

Standard

Heavy, type 9,6

Closing strips - Heavy, type 9,6

Standard

Closing strips - Standard

Type4,6

Narrow, type 5,61

Closing strips - Narrow, type 5,61

Special

Type 4,6 K

 - Type 4,6 K

Spring-loaded closing strip

 - Spring-loaded closing strip

Type3,84 F (Special)

Type 3,84 FK

 - Type 3,84 FK

Casing installation options

Winding casing is mounted to the wall, without thermal insulation

Winding casing is mounted to the wall, with combustible thermal insulation

Winding casing is mounted to the wall, with non-combustible thermal insulation

Closing strips

Standard

With window sill

Closing strips - With window sill

Standard

Closing strips - Standard

Guide rails

Standard

With non-combustible thermal insulation

Guide rails - With non-combustible thermal insulation

Without thermal insulation

Guide rails - Without thermal insulation

With combustible thermal insulation

Guide rails - With combustible thermal insulation

References

Product - BMW Group Research and Innovation Centre (FIZ), Munich

BMW Group Research and Innovation Centre (FIZ), Munich