• NL
  • Oplossingen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenties
  • Over Stöbich
  • Wereldmarktleider
  • Duurzaamheid
  • Actueel
  • Contact

Fibershield®-HC

  • Fibershield-HC

Productbeschrijving

In geval van alarm, elektromotorisch sluiten, ruimte-afsluiten of stralingsreducerende brandbeveiligingssluiting van textiel in horizontale installatiepositie en sluitrichting.

Systeem typeStralingsreducerende, ruimte-afsluitende brandwerende sluiting
BewijsCE-markering volgens EN 16034: 2014 in verband met EN 13241: 2003 + A2: 2016
Sluitrichtinghorizontal
BrandwerendheidE 120 | EW 90 | getest volgens EN 1634-1 : 2014-03 | ingedeeld volgens EN 13501-2 : 2016-12
SluitingscycliC, C1 | getest volgens EN 12605 : 2000-08 | ingedeeld volgens EN 13501-2 : 2016-12
Sluitcycli per uitvoeringC:     voor 2-delige systemen tot afmeting 9400 x 18800 mm voor E 120 en EW 60 resp. 6800 x 4270 mm voor EW 90
C1:   voor 1-delige systemen tot formaat 5000 x 5000 mm voor EW 60 of 6000 x 6500 mm voor E 120 en EW 30
MilieuconditiesIn geval van brand moet het vallen van plafonddelen, bijvoorbeeld in de buurt van de onthulling, door passende maatregelen ter plaatse worden voorkomen | Met bijzondere omgevingsomstandigheden (b.v. vochtigheid > 80%, omgevingstemperatuur < 5°C en > 45°C, windbelasting, enz.) wordt geen rekening gehouden
FiberShield-HC-Systemzeichnung

Legenda Systeemcomponenten:
1 = Rookmelder
2 = Behuizing
3 = Geleiderails
4 = Textiel
5 = Eindeelement
6 = Buismotor
7 = Regelmodule
8 = Bediening met bedieningseenheid
9 = Handbediend

Constructief systeemontwerp (systeemtekening)

ClassificatieMaat** [y x r] in mmBouwStofWanddikte in mmBehuizing (t x h)Geleiderail [a(+c) x b]
E 1206000 x 65001-tlgHeliotex 120300235 x 320200 x 80
EW 306000 x 65001-tlgHeliotex 120300235 x 320200 x 80
EW 605000 x 50001-tlgHeliotex 120300235 x 320200 x 80
E 1209400 x 188002-tlgHeliotex 120300400 x 610300 x 150
EW 609400 x 188002-tlgHeliotex 120300400 x 610300 x 150
EW 906800 x 42702-tlgHeliotex 120300400 x 610300 x 150

Inbouwvarianten


Inbouwvarianten Gehäuse Fibershield-HC
Onder het plafond

Omkasting


Omkasting Fibershield-HC
Geopende toestand
Omkasting Fibershield-HC
Gesloten toestand

Geleiderails


Geleiderails Fibershield-HC
Onder het plafond