• EN
  • World market leader
  • Sustainability
  • Solutions
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

    • Tube sealings

      Tube sealings

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

  • References
  • Theme worlds
  • News
  • Contact

Universal-S

Universal-S

Product description

The universal ceiling closure Universal-S is a sturdy damper construction for the space-saving installation in ceilings and floors. Application areas are, for instance, fire protection for vertical conveyors and discharge chutes. The system serves to shield supports with wall and ceiling penetrations and load-bearing equipment by means of circumferential collars. Depending on the installation situation, Universal-S is available as a single or multiple-part model. The vertical conveyor shaft does not require cladding. Universal-S meets the requirements of fire resistance class T 90 and is tested according to DIN 4102-5.

TypeFire protection closure as part of track-bound conveyor systems
Closing directionfrom left to right | from right to left
Fire resistanceT 90
Re-openingmanuel
Conveyor systemFloor conveyor | Discharge chutes | Vertical conveyor

Structural system design (system drawing)

Universal-S
a = 285 | b = 215 | c = 262 | s = 100 | M = 195
Required wall quality
Reinforced concreted ≥ 150 mm

Technical feasibility
LH400 mm - 900 mm
LB200 mm - 800 mm