• NL
  • Oplossingen
    • Fire Protection Bonnets

      Fire Protection Bonnets

      • Copy-Cap WV
      • Copy-Cap WH
    • Fire protection curtains

      Fire protection curtains

      In case of fire, fire protection curtains close wall and ceiling openings. Their construction (roll-down or folding technique) and the use of different fabrics provide for a wide range of applications as well as different protection goals, classifications and time classes. The casing and guide rails of the highly flexible systems blend almost invisibly into the building and allow plenty of scope for sophisticated architecture and open room concepts.

      • Fibershield®-P
      • Fibershield®-E
      • Fibershield®-I
      • Fibershield®-HC
      • Fibershield®-S
      • Fibershield®-F
    • Conveyor system closures

      Conveyor system closures

      Various production and logistics processes call for the most diverse types of conveyor systems. If these conveyor lines pass through fire-retardant or fire-resistant walls or ceilings, the openings required for this purpose must be provided with fire protection closures to prevent the spread of fire through the conveyor system or the goods conveyed. In the event of fire, conveyor system closures (CSC for short) must close these openings immediately and automatically. Fire resistance classified according to DIN EN 13501-2 is just as important as the smooth clearance of the closing areas in the event of a fire.

      • ECClos®-S
      • ECClos®-Q
      • ECClos®-FLEX-I
      • Ecotube
      • GCC
      • BR100
    • Smoke curtains

      Smoke curtains

      A smoke apron is a part of a smoke control system which also includes other components such as natural smoke and heat exhaust ventilators (EN 12101-2) and mechanical smoke and heat exhaust ventilators (EN 12101-3). Smoke aprons restrict the movement of combustion gases within a building in case of fire.

      • Supercoil
      • Stripecoil
      • Smokeshield-S
      • Fixed smoke apron
    • Smoke protection curtains

      Smoke protection curtains

      Once closed, smoke protection curtains (SPC) restrict the passage of smoke during the phase of fire formation, so that in the event of a fire, there is enough time to rescue people and animals from the room behind the curtain and to recover material assets without the need for respiratory equipment.

      • Fiberseal
    • Gates

      Gates

      The solution for issues with fire protection dampers in ventilation and air conditioning systems in conveyor processes. Stöbich offers fire protection for pneumatic conveyor lines the closing elements of which are not exposed to the flow of conveyed material. This way, the closing element cannot be damaged or contaminated by abrasive conveyed goods.

      • Omnicompact
    • Control units

      Control units

      Each automatic fire protection system needs a control unit. They are critical to safety, because a failure of this function means that the entire investment into a fire protection sealing has been in vain. Control units coordinate both fire detection and interaction with other control units, such as higher-level building control systems or clearing of the closing area of conveyor system closures.

      • RZ7
      • RZ3/4
      • RZ8
      • Battery system
      • Movipower 350/550
      • UPS
      • FFE-KDR
    • Special Solutions
      • ECClos®-D
      • ECClos®-K
      • Universal-B
      • Universal-S
      • ECClos®-FLEX
      • Collar
      • Turbocoil
      • Omnitube
    • Technical Fire Protection
      • Fire Multi Detektor
    • Fire protection for battery storage
      • Strainbox XS
      • Strainbox S
      • Strainbox L
      • Strainbox XL
      • Strainlock
      • Packaging Cushions
    • Service
  • Referenties
  • Over Stöbich
  • Wereldmarktleider
  • Duurzaamheid
  • Actueel
  • Contact

ECClos®-D

ECClos-D

Productbeschrijving

De bijzonder ruimtebesparende brandwerende deur is uitgevoerd als een tweevleugelige draaideurafsluiting. De twee geïntegreerde, half omhulde brandmanchetten omsluiten doorlopende aluminium of stalen rails (inclusief geleiderails) en sluiten deze af. Een thermische scheiding van de rail is niet nodig. De branddeuren kunnen zowel handmatig als motorisch worden geopend. ECClos®-D is geschikt voor doorlopende band-, rollen- en kettingtransporteurs, maar vooral voor elektrische monorails, ronde transportbanden en Power & Free systemen.

Systeem typeBrandwerende afsluiting bij railgebonden transportsystemen
Sluitrichtinghorizontaal draaiend
BrandwerendheidEI₁ 120 | getest volgens DIN EN 1366 | geclassificeerd volgens DIN EN 13501-2
SluitingscycliC3 aantal sluitcycli 50.000
Heropeninghandmatig
Lopende band systeemElektrisch monorailsysteem | Cirkeltransporteurs | Power & Free-systemen | Doorlopende transportbandtechnologie | Doorlopende rollenbaantechnologie | Doorlopende ondersteuning kettingtransporttechnologie

Constructief systeemontwerp (Tweevleugelig)

ECClos-D
a = 150 | c = 150 (met vast paneel) / 298 (kraag in deurblad) | s = 122
Benodigde wandkwaliteit
Metselwerkd ≥ 200 mm
Betond ≥ 200 mm
Gasbetond ≥ 200 mm
Montagewandend ≥ 160 mm
Beplankte staalbouwvolgens DIN 4102-4

Technische haalbaarheid
LH1000 mm - 5000 mm