  • Solutions
    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Références
  • Mondes thématiques
  • Leader du marché mondial
  • Durabilité
  • Actualités
  • Contact
Produit - Fiberseal-RS

Fiberseal

Système: Fibershield® | Série : Fiberseal

Description du produit

En cas d'alarme, fermeture automatique pare-fumée de construction textile ou non calorifuge coupe-feu et fumée rideau de protection en position d'installation verticale et en fermeture direction.

Fiberseal-RS

Type de construction

Fermeture pare-fumée de construction textile ou fermeture coupe-feu et pare-fumée non thermiquement isolante

Justificatif

Marquage CE selon EN 16034:2014 en combinaison avec EN 13241:2003+A2:2016

Sens de fermeture

Du haut vers le bas

Résistance au feu

E 0 – EW 120 • contrôlé selon EN 1634-1:2014+A1:2018 • classé selon la norme EN 13501-2:2016

Protection contre la fumée

classé selon EN 13501-2:2016

Cycles de fermeture

C0, C, C1, C2 • testé selon EN 12605:2000-08 et EN 12604:2017-12 • classé selon la norme EN 13501-2:2016

Comportement au feu du textile

A2-s1, d0; B-s1, d0; E-d2 • testé selon ISO 1716 et EN 13823 ou ISO 11295-2 • classé selon EN 13501-1:2018

Conditions environnementales

Des conditions environnantes particulières ne sont pas prises en considération (par ex. humidité de l’air > 80 %, température ambiante < 5 °C et > 45 °C, charges du vent, etc.)

Surfaces visibles

Galvanisées, couleur standard RAL et NCS

  • Fiberseal-RS
  • Fiberseal-RS
  • Fiberseal-RS
  • Fiberseal-RS
  • Fiberseal-RS
  • Fiberseal-RS
Structure constructive du système - Croquis du système

1Détecteur de fumée2Boîtier3Coulisse4Module de commande5Dispositif de déclenchementqHauteur constructive brute intérieurexLargeur constructive brute intérieuresHauteur du systèmerHauteur intérieure du systèmeyLargeur intérieure du systèmezLargeur du systèmetProfondeurhHauteurvDéportaLargeurb ProfondeurcRecouvrement


1Détecteur de fumée2Boîtier3Coulisse4Module de commande5Dispositif de déclenchementqHauteur constructive brute intérieurexLargeur constructive brute intérieuresHauteur du systèmerHauteur intérieure du systèmeyLargeur intérieure du systèmezLargeur du systèmetProfondeurhHauteurvDéportaLargeurb ProfondeurcRecouvrement

Classification
Protection contre
les incendies

Dimensions max.**
[y x r] en mm

Textile

Épaisseur de
paroi* en mm

Caisson

Coulisses

E 120

8792 x 5000

Heliotex

175

Typ B, C, D, E

Typ 1, 2

EW 90

8792 x 6000

Heliotex

150

Typ B, C, D, E

Typ 1, 2

EW 120

4340 x 2700

Heliotex

175

Typ B, C, D, E

Typ 1, 2

C2

7500 x 5000

Heliotex

Sa***

103,6 m

Protex 600 2S

150

Typ B, C, D, E

Typ 1, 2

Sa***

117,2 m

Protex 1100 2S

150

Typ B, C, D, E

Typ 1, 2

Sa***

76,8 m

Heliotex

150

Typ B, C, D, E

Typ 1, 2

S200

Surface 25,2 m2
Longueur de joint de 20,1 m

Protex 600 2S
Protex 1100 2S
Heliotex

* * La situation de montage doit être conforme aux exigences légales de construction du pays d'installation. La résistance au feu d'une construction porteuse de plafond ou de mur et des des éléments de construction adjacents doit correspondre au moins à celle de la fermeture coupe-feu et / ou pare-fumée, du rideau coupe-feu et / ou pare-fumée. La preuve de la stabilité et de l'aptitude au service des parois et éléments de construction adjacents doit être apportée dans les conditions ambiantes générales et en cas d'incendie. Voir également les indications relatives à la EN1366-7:2004 ou EN1363-1:2020. En cas d'incendie, le système de protection incendie ne doit pas être soumis à des charges supplémentaires autres que son propre poids. ne doit pas être exposée. ** dimensions supérieures sur demande *** La longueur du joint (normatif : 3 côtés sans baguette de finition) ne doit pas être dépassée. **** La surface et la longueur du joint (normatif : 4 côtés) ne doivent pas être dépassées.

Variantes de montage caisson

Montage au plafond

Montage mural

Montage mural plafond inférieur avec parement

Coulisses

Standard

Type 1 (montage mural)

Coulisses - Type 1 (montage mural)

Type 2 (montage dans l’intrados)

Coulisses - Type 2 (montage dans l’intrados)

Type 2 (montage en niche)

Coulisses - Type 2 (montage en niche)

Références

Produit - Nouvelle clinique de Minden

Nouvelle clinique de Minden

Produit - BV WINX / Maintor

BV WINX / Maintor

Produit - BMW Group Forschungs- und Innovationszentrum (FIZ), München

BMW Group Forschungs- und Innovationszentrum (FIZ), München

Produit - Salle de natation olympique, Munich

Salle de natation olympique, Munich

Produit - Schmidt Theater, Hamburg

Schmidt Theater, Hamburg

Produit - InnovationSPIN | Lemgo, Allemagne

InnovationSPIN | Lemgo, Allemagne

Produit - Musée Nolde | Seebüll, Allemagne

Musée Nolde | Seebüll, Allemagne