      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Références
  • Mondes thématiques
  • Leader du marché mondial
  • Durabilité
  • Actualités
  • Contact
Produit - Fibershield-E

Fibershield®-E

Description du produit

Standardisation élevée et donc système de cloisonnement économique avec système d'entraînement « gravitaire », c'est-à-dire fermeture sans énergie externe, de manière que des câbles résistant au feu ne sont pas nécessaires.

Nombre de cycles élevés des moteurs de 10 000 cycles. Diverses classifications possibles grâce à différents types de textile. Grands systèmes de rideaux coupe-feu au moins de classe C 2.

Possibilités d’équipement en option : barre palpeuse de sécurité, barre de lest à ressort

Fibershield-E

Type de construction

Rideau coupe-feu textile

Objectifs de protection pouvant être remplis

EI - avec zone exempte de charge d'incendie • EI - avec sprinkler

Textile

Heliotex • Ecotex 1100 A2

Zone exempte de charge d'incendie

Heliotex : EI 30/60/90 min 20/30/50 cm • Protex/Ecotex : EI 30/60/90 min 100/150/200 cm

Justificatif

UB III/B-06-005 • 3102/717/07 • UB 3.1/09-021 • UB III/B-08-012 • UB III/B-08-016

Sens de fermeture

Du haut vers le bas

Résistance au feu

E 30 • E 60 • E 90 • EW 30 • EW 60 • Classification selon DIN EN 13501-2

Cycles de fermeture

C2

  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
  • Fibershield-E
Structure constructive du système - Croquis du système

1Détecteurs de fumées2caisson3coulisses4consoles de fixation5toile6barre de lest7Tmoteur tubulaire8module de connexion9module de connexion, unité de contrôle10bouton manuel


1Détecteurs de fumées2caisson3coulisses4consoles de fixation5toile6barre de lest7Tmoteur tubulaire8module de connexion9module de connexion, unité de contrôle10bouton manuel

Classification

Fabric

System width (SB)

drop length (AL)

t

h

E 90 / EW 30

Ecotex 1100

≥ 1.1 m -≤ 3 m

≤ 3 m

200 mm

220 mm

EW 90

Heliotex EW

≥ 1.1 m -≤ 3 m

≤ 3 m

200 mm

220 mm

Special sizes on request - technically feasible up to a width of 7m (Ecotec 1100) or 6m (Heliotex)

Barres de lest

Standard

Standard

Barres de lest - Standard

Spécial

Barre de lest à ressort

 - Barre de lest à ressort

Typespécial

Variantes de montage caisson

Montage au mur

Sur une suspension

Montage au plafond

Coulisses

Standard

80 K

Coulisses - 80 K

a80 mmb60 mm

80 KB

Coulisses - 80 KB

a80 mmb60 mm

80 KN

Coulisses - 80 KN

a80 mmb60 mmaN85 mmbN70 mm

Références

Produit - Palais de justice, Amsterdam, Hollande

Palais de justice, Amsterdam, Hollande

Produit - Maison de la mer | Vienne, Autriche

Maison de la mer | Vienne, Autriche

Produit - EDGE Amsterdam West | Amsterdam, Pays-Bas

EDGE Amsterdam West | Amsterdam, Pays-Bas