      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Références
  • Mondes thématiques
  • Leader du marché mondial
  • Durabilité
  • Actualités
  • Contact
Produit - Fibershield-HC

Fibershield®-HC

Description du produit

En cas d'alarme, fermeture coupe-feu à fermeture électromotrice, fermant la pièce ou réduisant le rayonnement, de type textile, en position de montage et sens de fermeture horizontaux.

Fibershield-HC

Type de construction

Fermeture coupe-feu réduisant le rayonnement et fermant la pièce

Justificatif

Marquage CE selon la norme hEN 16034 : 2014 en liaison avec la norme hEN 13241 : 2003+A2 : 2016

Sens de fermeture

horizontal

Résistance au feu

E 120 • EW 90 • testé selon la norme EN 1634-1 : 2014-03 • classé selon la norme EN 13501-2 : 2016-12

Cycles de fermeture

C • C1 • testé selon la norme EN 12605 : 2000-08 • classé selon la norme EN 13501-2 : 2016-12

Durabilité

C1 pour systèmes en 1 partie jusqu'à la taille 5000 x 5000 mm pour EW60 ou 6000 x 6500 mm pour E120 et EW30 • C pour les systèmes en 2 parties jusqu'à la taille 9400 x 18800 mm pour E120 et EW60 ou 6800 x 4270 mm pour EW90

Conditions environnementales

En cas d'incendie, la chute, par exemple, d'éléments de plafond au niveau de l'embrasure doit être empêchée par des mesures appropriées prises par le maître d'ouvrage. Les conditions environnementales particulières ne sont pas prises en compte (par e • Des conditions environnementales particulières (par exemple, une humidité de l’air > 80 %, température ambiante < 5 °C et > 45 °C, charges de vent, etc.)

  • Fibershield-HC
  • Fibershield-HC
  • Fibershield-HC

Téléchargements

Structure constructive du système - Croquis du système

1Détecteur de fumée2Boîtier3Rails de guidage4Textile5Élément d'extrémité6Moteur tubulaire7Module de commande8Commande avec unité de commande9Déclenchement manuel


1Détecteur de fumée2Boîtier3Rails de guidage4Textile5Élément d'extrémité6Moteur tubulaire7Module de commande8Commande avec unité de commande9Déclenchement manuel

Classification

Taille

Type de construction

Tissu

Épaisseur de paroi

Boîtier (p x h)

Rail de guidage

E 120

6000 x 6500

1-tlg

Heliotex 120

300

235 x 320

200 x 80

EW 30

6000 x 6500

1-tlg

Heliotex 120

300

235 x 320

200 x 80

EW 60

5000 x 5000

1-tlg

Heliotex 120

300

235 x 320

200 x 80

E 120

9400 x 18800

2-tlg

Heliotex 120

300

400 x 610

300 x 150

EW 60

9400 x 18800

2-tlg

Heliotex 120

300

400 x 610

300 x 150

EW 90

6800 x 4270

2-tlg

Heliotex 120

300

400 x 610

300 x 150

Caisson

Standard

État ouvert

Caisson - État ouvert

État fermé

Caisson - État fermé

Variantes de montage caisson

Sous le plafond

Coulisses

Standard

Sous le plafond

Coulisses - Sous le plafond

Références

Produit - DaCapo College, Sittard

DaCapo College, Sittard

Produit - Olgakrippe, Stuttgart

Olgakrippe, Stuttgart

Produit - EDGE Amsterdam West | Amsterdam, Pays-Bas

EDGE Amsterdam West | Amsterdam, Pays-Bas