      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Références
  • Mondes thématiques
  • Leader du marché mondial
  • Durabilité
  • Actualités
  • Contact
Produit - Fibershield-S

Fibershield®-S

Description du produit

Une protection incendie qui fait le tour de l'angle : la surface de base de la fermeture peut être rectangulaire ou polygonale avec des angles compris entre 30° et 150°. Malgré la formation d'angles, aucun élément de soutien supplémentaire n'est nécessaire. Outre la forme polygonale fermée, il est également possible de réaliser des systèmes ouverts qui sont fixés au corps du mur à l'aide de rails de guidage spéciaux. Le système d'entraînement standard "Gravigen" permet de fermer le rideau coupe-feu sans énergie extérieure. Le Fibershield®-S permet de réaliser des géométries de cloisonnement exigeantes tout en satisfaisant aux exigences de fermeture des locaux pendant 90 minutes.

Fibershield-S

Type de construction

Rideau coupe-feu textile

Objectifs de protection pouvant être remplis

EI - avec zone exempte de charge d'incendie • EW 90 • EI - avec sprinkler

Textile

Ecotex 1100 A2 • Heliotex

Zone exempte de charge d'incendie

Protex/Ecotex : EI 30/60/90 min 100/150/200 cm • Heliotex : EI 30/60/90 min 20/30/50 cm

Justificatif

IBS 08062416

Sens de fermeture

Du haut vers le bas

Cycles de fermeture

C1

  • Fibershield-S
  • Fibershield-S
  • Fibershield-S
  • Fibershield-S
  • Fibershield-S
Structure constructive du système - Croquis du système

1Détecteurs de fumées2caisson3coulisses4moteur tubulaire5toile6barre de lest7 tube d'enroulement8 module de connexion9 unité de contrôle10 bouton manuelLgSLongueur du système


1Détecteurs de fumées2caisson3coulisses4moteur tubulaire5toile6barre de lest7 tube d'enroulement8 module de connexion9 unité de contrôle10 bouton manuelLgSLongueur du système

Textile

Étendue du système

Longueur de déroulement (AL)

t

h

Ecotex 1100 A2

< 50 m

< 3 m

490 mm

125 mm

Ecotex 1100 A2

< 50 m

> 3 m - ≤ 6 m

490 mm

225 mm

Heliotex EW 90

< 50 m

< 2,2 m

490 mm

125 mm

Heliotex EW 90

< 50 m

> 2,2 m - ≤ 2,5 m

490 mm

225 mm

Heliotex EW 90

< 50 m

> 4,5 m - ≤ 6 m

490 mm

450 mm

Barres de lest

Standard

Standard

Barres de lest - Standard

Spécial

Avec spots ou rampe lumineuse

 - Avec spots ou rampe lumineuse

Caisson

Standard

Caisson (ouvert)

Caisson - Caisson (ouvert)

h125 mmd290 mmt490 mm

Caisson (fermé)

Caisson - Caisson (fermé)

h125 mmd290 mmt490 mm

Spécial

Caisson EI (ouvert)

 - Caisson EI (ouvert)

h240 mmd560 mmt600 mm

Caisson EI (fermé)

 - Caisson EI (fermé)

h240 mmd560 mmt600 mm

Dispositif de sécurité (en option)

 - Dispositif de sécurité (en option)

h125 mmd290 mmt490 mmSSurveillance par infra-rouge

Coulisses

Standard

Coulisse pour polygones ouverts

Coulisses - Coulisse pour polygones ouverts

a117 mmb278 mm

Références

Produit - Cliniques de Bad Segeberg

Cliniques de Bad Segeberg